DocumentCode
3508945
Title
Surface membrane based bladder registration for evaluation of accumulated dose during brachytherapy in cervical cancer
Author
Noe, Karsten Ø ; Tanderup, Kari ; Sørensen, Thomas S.
fYear
2011
fDate
March 30 2011-April 2 2011
Firstpage
1253
Lastpage
1256
Abstract
A new optimisation strategy for surface mesh registration is proposed based on energy minimisation of an elastic surface membrane. The energy term is evaluated in three-dimensional space, optimisation however is performed while constraining the moving surface to a parametrised spherical space of the fixed surface. Optional landmark based matches can be included in the suggested iterative solver. The technique is demonstrated for bladder registration in brachytherapy treatment evaluation of cervical cancer. It holds promise to better estimate the accumulated but unintentional dose delivered to organs at risk.
Keywords
brachytherapy; cancer; medical image processing; mesh generation; accumulated dose; bladder registration; brachytherapy; cervical cancer; energy minimisation; optimisation strategy; surface membrane; surface mesh registration; Bladder; Brachytherapy; Geometry; Optimization; Springs; Surface treatment; Three dimensional displays; bladder; elastic model; radiotherapy; registation; spherical parametrisation;
fLanguage
English
Publisher
ieee
Conference_Titel
Biomedical Imaging: From Nano to Macro, 2011 IEEE International Symposium on
Conference_Location
Chicago, IL
ISSN
1945-7928
Print_ISBN
978-1-4244-4127-3
Electronic_ISBN
1945-7928
Type