• DocumentCode
    3508945
  • Title

    Surface membrane based bladder registration for evaluation of accumulated dose during brachytherapy in cervical cancer

  • Author

    Noe, Karsten Ø ; Tanderup, Kari ; Sørensen, Thomas S.

  • fYear
    2011
  • fDate
    March 30 2011-April 2 2011
  • Firstpage
    1253
  • Lastpage
    1256
  • Abstract
    A new optimisation strategy for surface mesh registration is proposed based on energy minimisation of an elastic surface membrane. The energy term is evaluated in three-dimensional space, optimisation however is performed while constraining the moving surface to a parametrised spherical space of the fixed surface. Optional landmark based matches can be included in the suggested iterative solver. The technique is demonstrated for bladder registration in brachytherapy treatment evaluation of cervical cancer. It holds promise to better estimate the accumulated but unintentional dose delivered to organs at risk.
  • Keywords
    brachytherapy; cancer; medical image processing; mesh generation; accumulated dose; bladder registration; brachytherapy; cervical cancer; energy minimisation; optimisation strategy; surface membrane; surface mesh registration; Bladder; Brachytherapy; Geometry; Optimization; Springs; Surface treatment; Three dimensional displays; bladder; elastic model; radiotherapy; registation; spherical parametrisation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Imaging: From Nano to Macro, 2011 IEEE International Symposium on
  • Conference_Location
    Chicago, IL
  • ISSN
    1945-7928
  • Print_ISBN
    978-1-4244-4127-3
  • Electronic_ISBN
    1945-7928
  • Type

    conf

  • DOI
    10.1109/ISBI.2011.5872629
  • Filename
    5872629