DocumentCode
351200
Title
A high voltage calibration method using the measuring spark gap
Author
Marinescu, Andrei ; Dumbrava, Ionel
Author_Institution
R&D Inst., ICMET, Craiova, Romania
Volume
1
fYear
1999
fDate
1999
Firstpage
222
Abstract
Spark gap use as a measuring system is still accepted by the international standards, in certain cases being an alternative for measuring circuit calibration. High voltage (HV) measurement is based on the experimental results of the calibrations carried out by several international laboratories and on the knowledge of correction factors corresponding to the atmospheric conditions during the test. The paper presents an updating of the process for atmospheric conditions measurement and for automatic determination of the spacing necessary to calibrate a voltage by means of the spark gap. Using the least squares method the analytical expression was determined under the form of interpolating polynomials for different voltage and sphere diameter types
Keywords
calibration; atmospheric conditions measurement; correction factors; high voltage calibration method; high voltage measurement; international standards; interpolating polynomials; measuring circuit calibration; measuring spark gap;
fLanguage
English
Publisher
iet
Conference_Titel
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location
London
ISSN
0537-9989
Print_ISBN
0-85296-719-5
Type
conf
DOI
10.1049/cp:19990547