DocumentCode :
351531
Title :
Experimental test of a diffused laser light optically pumped cesium beam frequency standard
Author :
Chen, Jingbiao ; Wang, Yiqiu ; Yiqiu Wang ; Yang, Donghai
Author_Institution :
Dept. of Electron., Peking Univ., Beijing, China
Volume :
1
fYear :
1999
fDate :
1999
Firstpage :
73
Abstract :
A new set-up of a diffused laser light optically pumped small cesium beam frequency standard has been successfully experimentally tested. Both the short term stability (2×10-11/√τ) and the long term stability (3.5×10-13 for a day sample time) have been measured. The light frequency shift caused by diffuse light was measured and calculated
Keywords :
atomic clocks; caesium; frequency stability; frequency standards; optical pumping; Cs; diffuse light; diffused laser light optically pumped cesium beam frequency standard; experimental test; light frequency shift; long term stability; short term stability; Frequency; Laser beams; Laser excitation; Masers; Optical beams; Optical pumping; Power lasers; Pump lasers; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Frequency and Time Forum, 1999 and the IEEE International Frequency Control Symposium, 1999., Proceedings of the 1999 Joint Meeting of the European
Conference_Location :
Besancon
ISSN :
1075-6787
Print_ISBN :
0-7803-5400-1
Type :
conf
DOI :
10.1109/FREQ.1999.840710