• DocumentCode
    3515475
  • Title

    Comparison of NaI(Tl) scintillators and high purity germanium for vehicle portal monitor applications

  • Author

    Ely, James H. ; Siciliano, Edward R. ; Kouzes, Richard T.

  • Author_Institution
    Pacific Northwest Lab., Richland, WA, USA
  • Volume
    3
  • fYear
    2004
  • fDate
    16-22 Oct. 2004
  • Firstpage
    1584
  • Abstract
    Radiation portal monitors are being deployed at international border crossings to detect illicit transport of radioactive material. Typically, vehicles which have a gamma-ray radiation signature above a certain gross-count threshold proceed through a more thorough inspection to locate and identify the source of radiation. Plastic scintillators (e.g., poly vinyl toluene (PVT)) are the most common gamma-ray detectors for portal monitors, mainly because of their relatively low cost for large-area, high-sensitivity detectors. Plastic scintillators provide gamma-ray detection, but limited spectroscopic information. Sodium iodide [NaI(Tl)] scintillator-based portal monitors can provide isotopic identification and may be useful where isotopic identification is needed. Recently, high purity germanium [HPGe]-based portal monitors have been evaluated since the increased resolution from HPGe can potentially provide isotopic identification more precisely and rapidly if deployed with adequate efficiency.
  • Keywords
    gamma-ray apparatus; gamma-ray detection; germanium radiation detectors; radiation monitoring; solid scintillation detectors; HPGe-based portal monitors; NaI(Tl) scintillator-based portal monitors; PVT scintillator; gamma-ray detection; gamma-ray detectors; gamma-ray radiation signature; gross-count threshold; high purity germanium-based portal monitors; illicit radioactive material transport; inspection; international border crossings; isotopic identification; large-area high-sensitivity detectors; plastic scintillators; poly vinyl toluene scintillator; radiation portal monitors; radiation source identification; radiation source location; sodium iodide scintillator-based portal monitors; spectroscopic information; vehicle portal monitor applications; Gamma ray detection; Gamma ray detectors; Germanium; Inspection; Plastics; Portals; Radiation detectors; Radiation monitoring; Radioactive materials; Vehicles;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2004 IEEE
  • Conference_Location
    Rome
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-8700-7
  • Electronic_ISBN
    1082-3654
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2004.1462543
  • Filename
    1462543