DocumentCode
3518539
Title
Fire Risk Analysis of Subway Station Fire on Different Ventilation Modes
Author
Tan Jia-lei ; Wang Tong ; Jin Long-zhe
Author_Institution
Beijing Municipal Inst. of Labour Protection, Beijing, China
Volume
1
fYear
2010
fDate
11-12 Nov. 2010
Firstpage
561
Lastpage
564
Abstract
The subway fire increases with the development of city development. The subway fire accidents gradually increase, which cause great casualties and property losses. In order to study this problem, the main fire risk source was studied on experiment. Peak temperature of platform roof can reach to 170°C on Y=0 m, and most passengers will die within short time on natural ventilation condition as no any countermeasure is applied. The low visibility is 0.5m, and which can make evacuation speed descend to 0.8m/s. Peak temperature of platform roof only reaches to 40°C on Y=0m when mechanical smoke exhaust system were used to exhaust smoke in fire. The visibility and smoke movement velocity is larger than those on natural ventilation condition. The results show that the mechanical smoke exhaust system is important on subway fire, and which provide an effective method to control smoke.
Keywords
exhaust systems; fires; railway accidents; railway safety; risk analysis; roofs; smoke; ventilation; casualty; city development; evacuation speed; fire risk analysis; fire risk source; mechanical smoke exhaust system; natural ventilation condition; platform roof; property loss; smoke movement velocity; subway fire accident; subway station fire; ventilation mode; mechanical smoke exhaust; natural ventilation; smoke; subway fire; temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
Optoelectronics and Image Processing (ICOIP), 2010 International Conference on
Conference_Location
Haiko
Print_ISBN
978-1-4244-8683-0
Type
conf
DOI
10.1109/ICOIP.2010.93
Filename
5663376
Link To Document