DocumentCode :
351872
Title :
Multiscale wavelet filter for high resolution radioisotopic images
Author :
Pousse, A. ; Dornier, C. ; Fagot, L. ; Parmentier, M. ; Kastler, B.
Author_Institution :
Lab. d´´Image et d´´Ingenierie pour la Sante, Univ. de Franche-Comte, Besancon, France
Volume :
1
fYear :
1999
fDate :
1999
Firstpage :
494
Abstract :
Radioisotopic investigations are very useful for functional diagnosis, but available gamma cameras have poor spatial resolution. Development of new PSPMT based high-resolution detectors brings new interests to this medical imaging technique. However, Poissonian nature of emitted photon flux and low count images due to low doses. Administered to the patients and to collimation, lead to images with granular aspect. This noisy appearance is particularly inconvenient when looking for cold nodules as in thyroid examinations. Low-pass filters, which reduce noise, are not well suited for detecting small cold nodules. An adapted translation invariant wavelet filter is designed which takes into account the Poissonian feature of noise and preserves small sized structures. Filter was tested on Monte Carlo simulations, phantom and clinical thyroid scintigraphies. Cold spherical nodules as small as 4 mm in diameter are easily detected on filtered images acquired with IRTS (ARIES) high-resolution gamma ray imaging probe. Presentation of filtered images at different scales offering enhanced visual quality and lowered noise; simultaneously with original image, allows more comfortable analysis and improves scintigraphic diagnosis ability
Keywords :
Monte Carlo methods; gamma-ray applications; gamma-ray detection; medical image processing; photomultipliers; position sensitive particle detectors; radioisotope imaging; wavelet transforms; Monte Carlo simulations; PSPMT based high-resolution detectors; Poissonian nature; adapted translation invariant wavelet filter; clinical thyroid scintigraphies; cold nodules; emitted photon flux; functional diagnosis; gamma cameras; high resolution radioisotopic images; high-resolution gamma ray imaging probe; low count images; medical imaging technique; multiscale wavelet filter; scintigraphic diagnosis; thyroid examinations; Biomedical imaging; Cameras; Collimators; Detectors; Image resolution; Imaging phantoms; Low pass filters; Noise reduction; Spatial resolution; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium, 1999. Conference Record. 1999 IEEE
Conference_Location :
Seattle, WA
ISSN :
1082-3654
Print_ISBN :
0-7803-5696-9
Type :
conf
DOI :
10.1109/NSSMIC.1999.842534
Filename :
842534
Link To Document :
بازگشت