DocumentCode :
3520176
Title :
Investigation of detector light response modeling for a thick continuous slab detector
Author :
Miyaoka, R.S. ; Lee, K.
Author_Institution :
Dept. of Radiol., Washington Univ., Seattle, WA, USA
Volume :
4
fYear :
2004
fDate :
16-22 Oct. 2004
Firstpage :
2479
Abstract :
We investigate a method to improve the position decoding for thick crystal versions (i.e., ≥8 mm) of our continuous miniature crystal element (cMiCE) PET detector by more accurately modeling the detector´s light response function (LRF). The LRF for continuous detectors varies with the depth of interaction (DOI) of the detected photon. This variation of the LRF can result in a positioning error for two-dimensional positioning algorithms. The effect is greatest for photons interacting directly over a PMT channel or near the edge of the crystal. We explore a method to improve positioning performance by deriving two look up tables (LUTs), from the collected data, corresponding to the front and back regions of the crystal. The DETECT2000 simulation package was used to investigate the light response characteristics for a 48.8 mm by 48.8 mm by 10 (8) mm slab of LSO coupled to a 64 channel, flat panel PMT. Using DETECT2000 the light collected for each PMT channel versus interaction location in three dimensions is known. The data are then combined to produce the two dimensional light collection histograms that one would experimentally measure. Light collection histograms that have markedly non-Gaussian distributions (e.g., bimodal or have a high-end tail) are characterized as a combination of two Gaussian functions, where each Gaussian function corresponds to a DOI region of the crystal. The results indicate modest gains in positioning accuracy are achieved near the central region of the crystal. However, significant improvements in spatial resolution and positioning bias are achieved for the corner section of the detector.
Keywords :
photomultipliers; position sensitive particle detectors; positron emission tomography; solid scintillation detectors; table lookup; 10 mm; 48.8 mm; 8 mm; DETECT2000 simulation package; DOI region; Gaussian functions; PMT channel; cMiCE PET detector; continuous miniature crystal element; depth of interaction; detector light response function; flat panel PMT; look up tables; nonGaussian distributions; position decoding; positioning error; spatial resolution; thick continuous slab detector; thick crystal versions; two dimensional light collection histograms; two-dimensional positioning algorithms; Decoding; Detectors; Histograms; Optical coupling; Packaging; Photonic crystals; Positron emission tomography; Probability distribution; Slabs; Table lookup;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Type :
conf
DOI :
10.1109/NSSMIC.2004.1462758
Filename :
1462758
Link To Document :
بازگشت