    This paper presents an advanced photovoltaic inverter which can deliver the maximum power from photovoltaic arrays to the utility grid for all sunlight conditions, as well as simultaneously providing power conditioning to suppress power line distortions. A new control strategy is developed to maximize the inverter output from the photovoltaic array and to suppress current harmonics in the power line using a single inverter configuration. A new control strategy and experimental results are given
  • Keywords
    interference suppression; invertors; photovoltaic power systems; power control; power system harmonics; solar cell arrays; active power line conditioning; current harmonics suppression; photovoltaic arrays; photovoltaic inverter; power conditioning; power line distortions suppression; sunlight conditions; utility grid; AC generators; Circuits; Digital signal processing; Inverters; Mesh generation; Photovoltaic systems; Power conversion; Power generation; Solar power generation; Space technology;