Abstract
Lead acid batteries are used in hybrid vehicles and telecommunications power supply. For reliable operation of these systems, an indication of state of charge of battery is essential. To determine the state of charge of battery, current integration method combined with open circuit voltage, is being implemented. To reduce the error in the current integration method the dependence of available capacity as a function of discharge current is determined. The current integration method is modified to incorporate this factor. The experimental setup built to obtain the discharge characteristics of the battery is presented.
Keywords
battery powered vehicles; hybrid electric vehicles; lead acid batteries; telecommunication power supplies; battery discharge characteristics; battery state-of charge; current integration method; discharge current; error reduction; hybrid vehicles; lead acid battery; open circuit voltage; system reliability; telecommunications power supply; Battery charge measurement; Battery powered vehicles; Current measurement; Gravity; Impedance measurement; Integrated circuit measurements; Monitoring; Power electronics; Power supplies; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics, 2006. IICPE 2006. India International Conference on
Conference_Location
Chennai
Print_ISBN
978-1-4244-3450-3
Electronic_ISBN
978-1-4244-3451-0
Type
conf
DOI
10.1109/IICPE.2006.4685347
Filename
4685347
Link To Document