DocumentCode :
35282
Title :
Design and Test of a High-Speed Flash ADC Mezzanine Card for High-Resolution and Timing Performance in Nuclear Structure Experiments
Author :
Egea, Francisco J. ; Sanchis, E. ; Gonzalez, V. ; Gadea, Andres ; Blasco, Jose M. ; Barrientos, Diego ; Dobon, J. J. Valiente ; Tripon, Michel ; Boujrad, Abderrahman ; Houarner, Charles ; Jastrzab, M. ; Blaizot, Maria ; Bourgault, Patrice ; de Angelis, G.
Author_Institution :
Inst. de Fis. Corpuscular (UV), Univ. Valencia, Valencia, Spain
Volume :
60
Issue :
5
fYear :
2013
fDate :
Oct. 2013
Firstpage :
3526
Lastpage :
3531
Abstract :
This work describes new electronics for the EXOGAM2 (HP-Ge detector array) and NEDA (BC501A-based neutron detector array). A new digitizing card with high resolution has been designed for gamma-ray and neutron spectroscopy experiments. The higher bandwidth requirement of the NEDA signals, together with the necessity for accuracy, require a high sampling rate in order to preserve the shape for real-time Pulse Shape Analysis (PSA). The PSA is of paramount importance for the NEDA to discriminate between neutrons and -ray signals. Both high resolution and high speed parameters are often difficult to achieve in a single electronic unit. These constraints, together with the need to build new digitizing electronics to improve performance and flexibility of signal analysis in nuclear physics experiments, led to the development a new FADC mezzanine card. In this work, the design and development are described, including the characterization procedure and the preliminary measurement results.
Keywords :
analogue-digital conversion; gamma-ray spectroscopy; germanium radiation detectors; neutron detection; neutron spectroscopy; nuclear electronics; signal processing; BC501A-based neutron detector array; EXOGAM2; FADC mezzanine card; HP-Ge detector array; NEDA signals; digitizing card; digitizing electronics; electronic unit; gamma-ray signals; gamma-ray spectroscopy experiments; high resolution high speed parameters; high sampling rate; high-speed flash ADC mezzanine card; neutron signals; neutron spectroscopy experiments; nuclear physics experiments; nuclear structure experiments; real-time pulse shape analysis; signal analysis; Bandwidth; Detectors; Educational institutions; Energy resolution; Frequency measurement; Histograms; Noise; $gamma$-ray spectroscopy; ADC; front-end; high-speed systems; low-noise electronics;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2013.2281241
Filename :
6616667
Link To Document :
بازگشت