DocumentCode
3528953
Title
Calculation of dosimetry parameters for 192Ir and 125I brachytherapy sources using Geant4
Author
Fonseca-Rodrigues, Sane S O ; Martins, Maximiano C. ; Begalli, Marcia ; Filho, Pedro P Queiroz ; De Souza-Santos, Denison
Author_Institution
Inst. for Radioprotection & Dosimetry (IRD), Rio de Janeiro, Brazil
fYear
2010
fDate
Oct. 30 2010-Nov. 6 2010
Firstpage
1190
Lastpage
1192
Abstract
In brachytherapy cancer treatments, methods for calculation of dose delivered to tumours and organs have been continuously improving. Monte Carlo methods are an important tool in dose calculation for brachytherapy cancer treatments, where the exposition to the source planning aims at the maximization of dose deposition in the target volume, while minimizing the deposition in healthy tissues. The use of interstitial brachytherapy sources follows the recommendations of AAPM REPORT No.51. The present work is based on Monte Carlo simulations with the Geant4 toolkit of the dose quantities recommended by that report. An Iridium-192 Buchler HDR source and an Iodine-125 LDR source were simulated and the geometry of dose deposition in media and energy spectra have been obtained. Calculations also include the Dose Rate Constant Λ, the Geometry Factor G(r,θ), the Anisotropy Function F(r, θ) and the Radial Dose Function g(r, θ).
Keywords
Monte Carlo methods; biological organs; brachytherapy; cancer; dosimetry; iodine; iridium; medical computing; optimisation; tumours; 125I; 192Ir; Geant4; Monte Carlo methods; anisotropy function; biological organs; cancer; dose deposition; dose rate constant; dosimetry; geometry factor; interstitial brachytherapy sources; maximization; radial dose function; source planning; tumours; Anisotropic magnetoresistance; Brachytherapy; Dosimetry; Geometry; Monte Carlo methods; Object oriented modeling; Phantoms;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location
Knoxville, TN
ISSN
1095-7863
Print_ISBN
978-1-4244-9106-3
Type
conf
DOI
10.1109/NSSMIC.2010.5873956
Filename
5873956
Link To Document