• DocumentCode
    3530243
  • Title

    Fault location in DC marine power system using multiple injections

  • Author

    Ke Jia ; Christopher, E. ; Sumner, M. ; Thomas, David

  • Author_Institution
    Nottingham Univ., Nottingham, UK
  • fYear
    2012
  • fDate
    11-14 Nov. 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    This paper introduced a fault localization method in DC Marine power system using multiple injection at two different locations. The experimental test results which were derived from the DC Marine system demonstrator show that the fault can be detected and located quickly and accurately. Accompany with the circuit breaker and the Bus Interface Unit (BIU), the load supply can be uninterrupted during fault situation.
  • Keywords
    fault location; marine power systems; power system faults; DC marine power system; bus interface unit; fault localization method; fault situation; load supply; multiple injections; Circuit breakers; Circuit faults; Fault location; Frequency estimation; Impedance; Power systems; Voltage measurement; Injection; Marine power system; fault location;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Renewable Energy Research and Applications (ICRERA), 2012 International Conference on
  • Conference_Location
    Nagasaki
  • Print_ISBN
    978-1-4673-2328-4
  • Electronic_ISBN
    978-1-4673-2329-1
  • Type

    conf

  • DOI
    10.1109/ICRERA.2012.6477472
  • Filename
    6477472