DocumentCode
3530243
Title
Fault location in DC marine power system using multiple injections
Author
Ke Jia ; Christopher, E. ; Sumner, M. ; Thomas, David
Author_Institution
Nottingham Univ., Nottingham, UK
fYear
2012
fDate
11-14 Nov. 2012
Firstpage
1
Lastpage
4
Abstract
This paper introduced a fault localization method in DC Marine power system using multiple injection at two different locations. The experimental test results which were derived from the DC Marine system demonstrator show that the fault can be detected and located quickly and accurately. Accompany with the circuit breaker and the Bus Interface Unit (BIU), the load supply can be uninterrupted during fault situation.
Keywords
fault location; marine power systems; power system faults; DC marine power system; bus interface unit; fault localization method; fault situation; load supply; multiple injections; Circuit breakers; Circuit faults; Fault location; Frequency estimation; Impedance; Power systems; Voltage measurement; Injection; Marine power system; fault location;
fLanguage
English
Publisher
ieee
Conference_Titel
Renewable Energy Research and Applications (ICRERA), 2012 International Conference on
Conference_Location
Nagasaki
Print_ISBN
978-1-4673-2328-4
Electronic_ISBN
978-1-4673-2329-1
Type
conf
DOI
10.1109/ICRERA.2012.6477472
Filename
6477472
Link To Document