Title :
Fault location in DC marine power system using multiple injections
Author :
Ke Jia ; Christopher, E. ; Sumner, M. ; Thomas, David
Author_Institution :
Nottingham Univ., Nottingham, UK
Abstract :
This paper introduced a fault localization method in DC Marine power system using multiple injection at two different locations. The experimental test results which were derived from the DC Marine system demonstrator show that the fault can be detected and located quickly and accurately. Accompany with the circuit breaker and the Bus Interface Unit (BIU), the load supply can be uninterrupted during fault situation.
Keywords :
fault location; marine power systems; power system faults; DC marine power system; bus interface unit; fault localization method; fault situation; load supply; multiple injections; Circuit breakers; Circuit faults; Fault location; Frequency estimation; Impedance; Power systems; Voltage measurement; Injection; Marine power system; fault location;
Conference_Titel :
Renewable Energy Research and Applications (ICRERA), 2012 International Conference on
Conference_Location :
Nagasaki
Print_ISBN :
978-1-4673-2328-4
Electronic_ISBN :
978-1-4673-2329-1
DOI :
10.1109/ICRERA.2012.6477472