• DocumentCode
    3531280
  • Title

    Depth-of-interaction compensation using a focused-cut scintillator for a pinhole gamma camera

  • Author

    Alhassen, Fares ; Kim, Sangtaek ; Gould, Robert G. ; Seo, Youngho ; Kudrolli, Haris ; Singh, Bipin ; Nagarkar, Vivek V.

  • Author_Institution
    Dept. of Radiol. & Biomed. Imaging, Univ. of California, San Francisco, San Francisco, CA, USA
  • fYear
    2010
  • fDate
    Oct. 30 2010-Nov. 6 2010
  • Firstpage
    1985
  • Lastpage
    1986
  • Abstract
    Preclinical SPECT can potentially be a powerful platform to study fundamental biological processes and drug interactions in small animals. Gamma cameras for such SPECT systems require high spatial resolutions in order to adequately map the uptake of radioisotopes in small animals. Pinhole collimators offer one of the best technically feasible ways to achieve a high resolution. However, pinhole geometry introduces parallax errors, particularly toward the edge of the field of view, limiting the system spatial resolution. The parallax errors arise from the variable depth of interaction (DOI) of gammaray/scintillator events, especially when gamma rays enter a scintillator at steep angles. There have been several efforts to address parallax errors in pinhole SPECT, including algorithm-based DOI modeling and correction and the use of a curved fiber bundle to collimate light from a curved scintillator. Another way to overcome parallax errors in a pinhole gamma camera is to use a focused-cut scintillator, which is pixellated so that the pixels are focused towards the pinhole of a collimator. Thus, the path of a primary ray that has passed through the pinhole only intersects with a single pixel in the scintillator. Here, we experimentally test a pinhole gamma camera with a focused-cut (FC) scintillator. We measure the resolution across a continuous scintillator and across a straight-cut (SC) pixellated scintillator and show that the thicker FC scintillator has comparable parallax error in comparison with a thinner SC scintillator (3 mm vs. 1 mm). Thus, FC scintillators are shown to offer both the high resolution of thin pixellated scintillators and the high sensitivity of thicker scintillators.
  • Keywords
    collimators; scintillation counters; single photon emission computed tomography; algorithm-based DOI modeling; curved fiber bundle; depth-of-interaction compensation; drug interaction; focused-cut scintillator; pinhole collimator; pinhole gamma camera; preclinical SPECT; spatial resolution; straight-cut pixellated scintillator; Biomedical imaging; Cameras; Collimators; Detectors; Pixel; Spatial resolution; Single photon emission computed tomography; biomedical applications of nuclear radiation; biomedical nuclear imaging; scintillation detectors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
  • Conference_Location
    Knoxville, TN
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-9106-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2010.5874122
  • Filename
    5874122