DocumentCode :
3531502
Title :
Collimator interchange system for adaptive cardiac imaging in C-SPECT
Author :
Rozler, Mike ; Liang, Haoning ; Chang, Wei
Author_Institution :
Dept. of Diagnostic Radiol., Rush Univ. Med. Center, Chicago, IL, USA
fYear :
2010
fDate :
Oct. 30 2010-Nov. 6 2010
Firstpage :
2055
Lastpage :
2060
Abstract :
Use of a small field of view can greatly improve the imaging performance of cardiac SPECT systems, compared to using conventional whole-body SPECT system that use a large field of view for cardiac imaging. To maximize the benefits, however, it is important to locate the heart and place it accurately into the small FOV. To achieve high performance across the general population, a system must provide imaging configurations optimized for different size and location of the heart and the size of the patient. Because of the critical role the collimator plays in SPECT, it would be ideal if a dedicated collimator could be used for each of the different patient groups. The ability to exchange collimators without moving the patient can enable serial studies with different imaging options while preserving anatomic registration. We developed a slit exchange system for the slit-slat collimator of the C-SPECT cardiac platform. The full-scale prototype, a precision link conveyor following a curved, body contouring path, allows four distinct transaxial collimation options and can be expanded further. The collimators can be exchanged in 10 seconds without disturbing the patient, allowing truly adaptive clinical SPECT imaging The positioning precision for all elements of the system is within 0.1 mm and has shown no degradation over 100,000 complete revolutions of the conveyor - well above the expected usage for a clinical system. We believe that the rapid and precise operation allowing optimal collimation for different imaging tasks is an important technological step for SPECT.
Keywords :
cardiology; collimators; conveyors; image registration; medical image processing; single photon emission computed tomography; adaptive cardiac imaging; anatomic registration; body contouring path; cardiac SPECT systems; collimator interchange system; conventional whole-body SPECT system; four distinct transaxial collimation options; imaging configurations; optimal collimation; precision link conveyor; rapid operation; slit exchange system; slit-slat collimator; Cameras; Collimators; Detectors; Heart; Histograms; Position measurement; Imaging; SPECT; collimator; instrumentation; system design;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location :
Knoxville, TN
ISSN :
1095-7863
Print_ISBN :
978-1-4244-9106-3
Type :
conf
DOI :
10.1109/NSSMIC.2010.5874138
Filename :
5874138
Link To Document :
بازگشت