• DocumentCode
    3532188
  • Title

    Cramer-Rao bound for gated PET

  • Author

    Cloquet, Christophe ; Goldman, Serge ; Defrise, Michel

  • Author_Institution
    Dept. of Nucl. Med., Univ. Libre de Bruxelles, Brussels, Belgium
  • fYear
    2010
  • fDate
    Oct. 30 2010-Nov. 6 2010
  • Firstpage
    2267
  • Lastpage
    2272
  • Abstract
    Respiratory and cardiac motions degrade the spatial resolution in PET and SPECT imaging, with a negative impact on the diagnostic accuracy for cardiac studies and for the detection of lung tumors. The goal of this work is to determine the limit on the achievable performance in gated PET reconstruction with joint motion estimation, without external data, using the Cramer-Rao lower bound (CRLB). For a single ring scanner and a simple beating phantom we compute the CRLB with and without motion estimation. This comparison gives an insight into the increase in the number of events required to obtain in the presence of motion the same variance as with an hypothetical scan without motion. This preliminary study assumes an unbiased estimator for the image coefficients. The importance of the bias is however illustrated for a problem without motion and for the bias corresponding to a specific algorithm, OSEM with 7 subsets and 8 iterations. The empirical variance observed with that algorithm is lower than the unbiased CRLB but, as expected, higher than the biased CRLB. When the number of counts decreases below a certain threshold, the difference between the unbiased and biased CRLBs increases dramatically, and in addition the variance of the OSEM reconstruction becomes significantly higher than the lower bound given by the CRLB with the corresponding bias. Finally, we set up a direction to estimate the CRLB for larger images, by approximating the bound using a submatrix of the Fisher matrix.
  • Keywords
    cardiology; image reconstruction; lung; medical image processing; motion estimation; phantoms; pneumodynamics; positron emission tomography; tumours; CRLB; Cramer-Rao lower bound; Fisher matrix; cardiac motion; empirical variance; gated PET; joint motion estimation; lung tumors; respiratory motion; simple beating phantom; single ring scanner; Cramer-Rao bounds; Image reconstruction; Logic gates; Motion estimation; Phantoms; Pixel; Positron emission tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
  • Conference_Location
    Knoxville, TN
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-9106-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2010.5874187
  • Filename
    5874187