• DocumentCode
    3532336
  • Title

    Justification of an alternative system for one- and two-dimensional magnetic measurements

  • Author

    Krah, I.H. ; Engdahl, C.

  • Author_Institution
    Dept. of Electr. Eng., R. Inst. of Technol., Stockholm, Sweden
  • fYear
    2005
  • fDate
    4-8 April 2005
  • Firstpage
    709
  • Lastpage
    710
  • Abstract
    A novel two-dimensional measurement set-up for magnetic sheet characterization has been designed and constructed. Experimental verification shows that the inhomogeneity of the magnetic flux through the sample was smaller than the measurement error, whereas the required electric excitation decreased considerably. The aim of this paper is to prove that the new measurement system is superior to the Epstein frame and the rotational single sheet tester (RSST) and can be recommended.
  • Keywords
    magnetic field measurement; magnetic flux; magnetic sensors; Epstein frame; electric excitation; magnetic flux; magnetic measurements; magnetic sheet; measurement error; rotational single sheet tester; Coils; Magnetic anisotropy; Magnetic field measurement; Magnetic flux; Magnetic flux leakage; Magnetic materials; Magnetic variables measurement; Nonuniform electric fields; Perpendicular magnetic anisotropy; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Magnetics Conference, 2005. INTERMAG Asia 2005. Digests of the IEEE International
  • Print_ISBN
    0-7803-9009-1
  • Type

    conf

  • DOI
    10.1109/INTMAG.2005.1463783
  • Filename