DocumentCode :
3533040
Title :
Influence of magnetic saturation on sensorless-controlled interior permanent magnet synchronous motors
Author :
Orlik, T. ; Klock, Jan ; Schumacher, Walter
Author_Institution :
Inst. fur Regelungstech., Tech. Univ. Braunschweig, Braunschweig, Germany
fYear :
2013
fDate :
2-6 Sept. 2013
Firstpage :
1
Lastpage :
10
Abstract :
This contribution investigates the influence of magnetic saturation on the sensorless control of IPM synchronous motors. An extended analytical motor model is introduced that covers magnetic anisotropies and describes the fundamental wave as well as the harmonic characteristics. Simulation results are compared to actual measurements on a servo drive.
Keywords :
magnetic anisotropy; permanent magnet motors; sensorless machine control; servomotors; synchronous motors; IPM synchronous motors; analytical motor model; interior permanent magnet synchronous motors; magnetic anisotropy; magnetic saturation; sensorless control; servo drive; Couplings; Inductance; Magnetic hysteresis; Perpendicular magnetic anisotropy; Saturation magnetization; Stators; Harmonics; Modelling; Sensorless control; Synchronous motor;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Applications (EPE), 2013 15th European Conference on
Conference_Location :
Lille
Type :
conf
DOI :
10.1109/EPE.2013.6631753