DocumentCode :
3533892
Title :
Comparison of three electrical capacitance tomography systems
Author :
Chen, Dixiang ; Yang, Wuqiang ; Deng, Xiang
Author_Institution :
Sch. of Mechatron. Eng. & Autom., Nat. Univ. of Defense Technol., Changsha, China
fYear :
2010
fDate :
1-2 July 2010
Firstpage :
57
Lastpage :
62
Abstract :
Electrical capacitance tomography (ECT) has been developed for two decades to visualize the internal behavior of industrial processes containing dielectric components. Three different ECT systems have been developed: (1) based on a charge/discharge capacitance measuring circuit, (2) based on an AC circuit and (3) based on an impedance analyzer. In this paper the operation principles, calibration methods and some performance of the three systems are compared. The experimental results prove that the AC-based ECT system is superior to the charge/discharge ECT system. Although the impedance analyzer based ECT system can provide the highest accuracy and the best image quality, it is bulky and expensive.
Keywords :
calibration; capacitance measurement; dielectric devices; electric impedance imaging; tomography; AC circuit; ECT system; charge-discharge capacitance measuring circuit; dielectric components; image quality; impedance analyzer; industrial processes; three electrical capacitance tomography systems; Calibration; Capacitance measurement; Charge measurement; Circuits; Current measurement; Dielectric measurements; Electrical capacitance tomography; Image analysis; Impedance measurement; Visualization; ECT; calibration; charge/discharge; impedance analyzer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Imaging Systems and Techniques (IST), 2010 IEEE International Conference on
Conference_Location :
Thessaloniki
Print_ISBN :
978-1-4244-6492-0
Type :
conf
DOI :
10.1109/IST.2010.5548441
Filename :
5548441