• DocumentCode
    3534015
  • Title

    Maximum a Posteriori Reconstruction using PRESTO and PET/MR data acquired Simultaneously with the 3TMR-BrainPET

  • Author

    Caldeira, L. ; Scheins, J.J. ; Almeida, P. ; Seabra, J. ; Herzog, H.

  • Author_Institution
    Inst. of Biomed. Eng. & Biophys., Univ. of Lisbon, Lisbon, Portugal
  • fYear
    2010
  • fDate
    Oct. 30 2010-Nov. 6 2010
  • Firstpage
    2879
  • Lastpage
    2884
  • Abstract
    In this paper, a Maximum a Posteriori Reconstruction algorithm is applied for the first time to the Siemens 3TMR BrainPET scanner. The implementation of this algorithm is done in the PET REconstruction Software TOolkit. This software is able to cope with 3D PET listmode data and can deal with the specificities of the Siemens 3TMR BrainPET scanner. Simulated data was used to assess the performance of the algorithm. Several a priori distributions were tested and the results are compared to OSEM reconstruction. Simultaneously acquired PET and MR data of a human patient was used to show the feasibility of the Maximum a Posteriori algorithm. The results are promising and expected to improve clinical applications.
  • Keywords
    biomedical MRI; brain; image reconstruction; maximum likelihood estimation; medical image processing; positron emission tomography; 3D PET listmode data; 3TMR-BrainPET; OSEM reconstruction; PET reconstruction software toolkit; PRESTO; maximum a posteriori reconstruction; Image reconstruction; Image segmentation; Noise; Photonics; Pixel; Positron emission tomography; Software; 3TMR-BrainPET; Maximum a Posteriori; PRESTO; Reconstruction;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
  • Conference_Location
    Knoxville, TN
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-9106-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2010.5874322
  • Filename