Abstract :
Results of PD tests in vegetable oil impregnated insulating system are discussed in this paper. The main objective of the study is to investigate the PD behaviour in the particular insulating systems at elevated temperature. Two different sample arrangements of electrical pressboard and insulating paper were used to simulate insulation defects. The sample was placed in a glass cell and was fully immersed in vegetable oil. The initiated PDs were detected and analysed using a wide band PD detector. The PD waveforms were picked up by means of a HFCT sensor and displayed using a digital oscilloscope. Investigation results show that there are some differences in intrinsic characteristics of PD pulses measured from the two different sample configurations.
Keywords :
oscilloscopes; sensors; transformer insulation; vegetable oils; HFCT sensor; PD pulse measurement; PD waveforms; digital oscilloscope; electrical pressboard; elevated temperature; glass cell; insulation defect simulation; transformer insulating system; vegetable-oil-impregnated insulation system; wide band PD detector; Current measurement; Detectors; Manuals; Oil insulation; Power transformer insulation; impregnated insulating system; partial discharge; vegetable oil;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Properties and Applications of Dielectric Materials (ICPADM), 2012 IEEE 10th International Conference on the
Conference_Location :
Bangalore
ISSN :
2160-9225
Print_ISBN :
978-1-4673-2852-4
Type :
conf
DOI :
10.1109/ICPADM.2012.6318931
Filename :
6318931
Link To Document :
بازگشت