DocumentCode :
3536651
Title :
Recent development of TlBr gamma-ray detectors
Author :
Tanaka, Tomonobu ; Hitomi, Keitaro ; Tada, Tsutomu ; Kim, Seong-Yun ; Wu, Yan ; Shoji, Tadayoshi ; Yamazaki, Hiromichi ; Ishii, Keizo
Author_Institution :
Dept. of Electron. & Intell. Syst., Tohoku Inst. of Technol., Sendai, Japan
fYear :
2010
fDate :
Oct. 30 2010-Nov. 6 2010
Firstpage :
3927
Lastpage :
3921
Abstract :
Planar detectors, strip detectors and double-sided strip detectors were fabricated from TlBr crystals grown by the traveling molten zone method using zone-purified material. The detector performance including the leakage current, energy resolutions and timing performance were evaluated in order to assess the capability of the detectors for PET and SPECT applications. The TlBr detectors exhibited excellent spectroscopic performance at room temperature. An energy resolution of 3.4% FWHM at 511 keV was obtained from a TlBr planar detector 1 mm thick. A TlBr strip detector 1 mm thick with four anode strip electrodes exhibited almost uniform detector performance over the strips with the average energy resolution of 4.4% FWHM at 511 keV. A TlBr double-sided strip detector exhibited an energy resolution of 6.3% FWHM for 122 keV gamma-rays. Coincidence timing spectra between a TlBr planar detector and a BaF2 scintillation detector were recorded at room temperature. Timing resolutions of 14 ns and 24 ns were obtained from TlBr detectors 0.5 mm and 1 mm thick, respectively. By cooling the detector to 0°C, an improved timing resolution of 12 ns was obtained from a TlBr detector 1 mm thick.
Keywords :
coincidence techniques; crystal growth from melt; leakage currents; positron emission tomography; semiconductor counters; semiconductor growth; single photon emission computed tomography; solid scintillation detectors; thallium compounds; BaF2 scintillation detector; PET applications; SPECT applications; TlBr; TlBr crystals; TlBr gamma-ray detectors; TlBr planar detector; anode strip electrodes; coincidence timing spectra; detector performance; double sided strip detectors; electron volt energy 122 keV; electron volt energy 511 keV; energy resolution; leakage current; planar detectors; room temperature spectroscopic performance; timing performance; traveling molten zone; zone purified material; Crystals; Detectors; Electrodes; Energy resolution; Strips; Temperature measurement; Timing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location :
Knoxville, TN
ISSN :
1095-7863
Print_ISBN :
978-1-4244-9106-3
Type :
conf
DOI :
10.1109/NSSMIC.2010.5874551
Filename :
5874551
Link To Document :
بازگشت