Comparison of the X-ray performance of small pixel CdTe and CZT detectors
Author :
Wilson, Matthew D. ; Barnes, Paul ; Cernik, Robert C. ; Hansson, Conny C T ; Jacques, Simon ; Jones, Lawrence L. ; Seller, Paul ; Sellin, Paul J. ; Sochi, Taha ; Veale, Matthew C. ; Veeramani, Peruami ; Withers, Philip J. ; Youd, Christopher P.
Author_Institution :
Rutherford Appleton Lab., Sci. & Technol. Facilities Council, Didcot, UK
fYear :
2010
fDate :
Oct. 30 2010-Nov. 6 2010
Firstpage :
3942
Lastpage :
3946
Abstract :
The Rutherford Appleton Laboratory has built a small pixel detector for spectroscopic measurements of high energy X-rays using CdTe and CdZnTe. The detector has an array of 20×20 pixels on a 250μm pitch with each pixel bonded to a separate channel on an application specific integrated circuit (ASIC). Each channel in the ASIC contains a charge preamplifier, leakage current compensation circuit, shaping amplifier and peak hold circuit. In recent years there has been an increase in the availability of high quality CdTe and CdZnTe material and the contacting technology required for low leakage current small pixel devices. The energy resolution and stability of the X-ray performance of 1mm thick CdTe with Aluminum Schottky contact pixels and 2mm thick CdZnTe grown by travelling heater method (THM) are measured. The CdTe detectors had an energy resolution of 1 to 1.1keV at 75keV. The THM CdZnTe had an energy resolution of 1.3keV at 75keV. The stability of the performance was measured over a 12 hour exposure with the detectors biased to -500V and held at 25°C. The CdZnTe exhibited stable performance whereas the CdTe suffered from bias induced polarization, the onset of which was delayed by cooling the detectors to 12°C.
Keywords :
X-ray detection; application specific integrated circuits; cadmium compounds; semiconductor counters; ASIC; CdZnTe; THM; X-ray performance; application specific integrated circuit; charge preamplifier; electron volt energy 1 keV to 1.1 keV; electron volt energy 1.3 keV; electron volt energy 75 keV; high energy X-rays; leakage current compensation circuit; peak hold circuit; pixel CZT detector; pixel CdTe detector; shaping amplifier; spectroscopic measurement; temperature 25 degC; travelling heater method; Anodes; Application specific integrated circuits; Detectors; Energy resolution; Lead; Materials; Pixel;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location :
Knoxville, TN
ISSN :
1095-7863
Print_ISBN :
978-1-4244-9106-3
Type :
conf
DOI :
10.1109/NSSMIC.2010.5874554
Filename :
5874554
Link To Document :
بازگشت