DocumentCode :
3537729
Title :
Factor for dielectric strength reduction due to fibrous contaminants in XLPE
Author :
Iinuma, K. ; Miyata, Hiroyuki ; Takahashi, Tohru ; Yamamoto, Shuji
Author_Institution :
Fujikura Ltd., Japan
fYear :
1995
fDate :
17-20 Sep 1995
Firstpage :
105
Lastpage :
108
Abstract :
We investigate the effect on breakdown strength reduction by employing several kinds of fiber, in which each effect is classified in prebreakdown by partial discharge detection and electroluminescence measurement. In the same size fiber, breakdown strength decreases in the order: solid synthetic fiber>cotton fiber>hollow synthetic fiber>copper fiber. The partial discharge behavior is clearly different between hollow fiber and copper fiber. The electrical tree characteristics are also discussed
Keywords :
XLPE insulation; electric breakdown; electric strength; electroluminescence; fibre reinforced composites; impurities; insulation testing; partial discharges; trees (electrical); XLPE; breakdown strength reduction; copper fiber; cotton fiber; dielectric strength reduction; electrical tree characteristics; electroluminescence; fibrous contaminants; hollow synthetic fiber; partial discharge detection; prebreakdown; solid synthetic fiber; Copper; Cotton; Dielectric breakdown; Electric breakdown; Electroluminescence; Optical fiber testing; Partial discharge measurement; Partial discharges; Shape measurement; Solids;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulating Materials, 1995. International Symposium on
Conference_Location :
Tokyo
Print_ISBN :
4-88686-047-8
Type :
conf
DOI :
10.1109/ISEIM.1995.496519
Filename :
496519
Link To Document :
بازگشت