Abstract
We investigate the effect on breakdown strength reduction by employing several kinds of fiber, in which each effect is classified in prebreakdown by partial discharge detection and electroluminescence measurement. In the same size fiber, breakdown strength decreases in the order: solid synthetic fiber>cotton fiber>hollow synthetic fiber>copper fiber. The partial discharge behavior is clearly different between hollow fiber and copper fiber. The electrical tree characteristics are also discussed
Keywords
XLPE insulation; electric breakdown; electric strength; electroluminescence; fibre reinforced composites; impurities; insulation testing; partial discharges; trees (electrical); XLPE; breakdown strength reduction; copper fiber; cotton fiber; dielectric strength reduction; electrical tree characteristics; electroluminescence; fibrous contaminants; hollow synthetic fiber; partial discharge detection; prebreakdown; solid synthetic fiber; Copper; Cotton; Dielectric breakdown; Electric breakdown; Electroluminescence; Optical fiber testing; Partial discharge measurement; Partial discharges; Shape measurement; Solids;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulating Materials, 1995. International Symposium on
Conference_Location
Tokyo
Print_ISBN
4-88686-047-8
Type
conf
DOI
10.1109/ISEIM.1995.496519
Filename
496519
Link To Document