DocumentCode :
3538031
Title :
Developing a stimulator and an interface for FES-cycling rehabilitation system
Author :
Khosravani, S. ; Lahimgarzadeh, N. ; Maleki, A.
Author_Institution :
Dept. of Biomed. Eng., Amirkabir Univ. of Technol., Tehran, Iran
fYear :
2011
fDate :
14-16 Dec. 2011
Firstpage :
175
Lastpage :
180
Abstract :
FES cycling system is introduced as a beneficial rehabilitation method for restoring muscle function in SCI patients. The system is made up of three main parts: a cycling device, a controller and an electrical stimulator. In this paper, a commercial motorized bicycle was augmented with an electrical muscle stimulator and a pedal observation interface. Firstly, a six-channel electrical stimulator was designed and manufactured whose output consists of current pulses (faradic/bursting stimulation pulses) with a wide range of rectangular waveforms (monophasic/biphasic) ranging from 0-150 mA with steps of 0.6 mA and time resolution of 5 μs. The device is capable of receiving position feedback data from the cranks and exchanging data with the computer via serial connection, that is, it is capable of sending the cycling speed to the computer and receiving two groups of commands from the computer: the commands, needed for adjusting the frequency and pulse width of the output signals as well as the commands needed for activating the desired stimulation channel at different time intervals. The main advantages of the device are the high level of output current amplitude, the capability of fine time and amplitude tuning, the vast range of output waveforms, and the use of low cost electronics components in its structure which makes it economically efficient for being used in various FES research studies, specially FES-cycling. Secondly, a commercial motorized bicycle (Viva1) is equipped with a pedal observation interface. The device receives the signal produced by the shaft encoder attached to the motor of the bicycle and uses this data in order to calculate the cycling speed and provide an angular position index which is consequently fed to an electromyography device and helps with the process of determining muscle recruitment pattern in FES-cycling.
Keywords :
biomedical equipment; electromyography; injuries; medical signal processing; neuromuscular stimulation; patient rehabilitation; FES-cycling rehabilitation system; SCI patient; amplitude tuning; angular position index; computer; controller; cranks; cycling device; cycling speed; data exchange; electrical muscle stimulator; electromyography device; low cost electronics components; motorized bicycle; muscle function; muscle recruitment pattern; output current amplitude; pedal observation interface; position feedback data; rectangular waveforms; serial connection; shaft encoder; six-channel electrical stimulator; Bicycles; Biomedical engineering; Computers; Low voltage; Muscles; Neuromuscular stimulation; Physiology;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Engineering (ICBME), 2011 18th Iranian Conference of
Conference_Location :
Tehran
Print_ISBN :
978-1-4673-1004-8
Type :
conf
DOI :
10.1109/ICBME.2011.6168550
Filename :
6168550
Link To Document :