DocumentCode
3548130
Title
Numerical study on drug delivery vehicle motion characteristics in tumor-defective blood vessels using arbitrary Lagrangian-Eulerian Algorithm
Author
Liao, Yu-chung ; Rei-Yu Chein
Author_Institution
Dept. of Mech. Eng., Nat. Chung Hsing Univ., Taichung, Taiwan
fYear
2013
fDate
10-13 Nov. 2013
Firstpage
101
Lastpage
106
Abstract
This study presented numerical study on the motion of drug delivery vehicle (DDV) in blood vessel based the enhanced permeability and retention (EPR) effect due to the tumor-defective blood vessel. Instead of traditional particle tracing, the arbitrary Lagrangian-Eulerian Algorithm (ALE) was employed in this study to account for the force coupling between the moving DDV and blood flow. The ALE and Navier-Stokes modules facilitated by COMSOL software were employed to carry out the numerical simulations. The computational domain was treated as two-dimensional containing three trans-cellular holes caused by the tumor tissue growth. Motions of both spherical and rod-like DDV were considered in this study. The DDV was considered to enter the tumor tissues when it traveled through the defective opening gaps. The simulated results indicated that the initial locations and size played importation roles on governing the motion of DDV. The DDV had greater chance to travel through the opening gaps when its initial location was close to the vessel wall and its diameter ranged between 20 and 100 nm. The numerical simulations also demonstrated that there was significant difference on the DDV trajectories between ALE and particle tracing computations. The motion characteristics of the rod-like DDV was similar to that of its spherical counterpart except the inclusion of rotational motion. The rod-like DDV had less chance of entering the tumor tissue as compared with the spherical DDV because of its rotational motion.
Keywords
Navier-Stokes equations; blood; blood vessels; cancer; drug delivery systems; drugs; flow simulation; haemodynamics; numerical analysis; permeability; tumours; COMSOL software; Navier-Stokes modules; arbitrary Lagrangian-Eulerian algorithm; blood flow; computational domain; drug delivery vehicle motion characteristics; enhanced permeability; force coupling; numerical simulations; retention effect; rod-like DDV; rotational motion; size 20 nm to 100 nm; spherical DDV; traditional particle tracing; tumor tissue growth; tumor-defective blood vessels; two-dimensional containing three trans-cellular holes; Blood vessels; Drug delivery; Electrostatics; Force; Hydrodynamics; Trajectory; Tumors; Arbitrary Lagrangian-Eulerian algorithm (ALE); Drug delivery vehicle (DDV); Enhanced permeability and retention (EPR); blood vessel; defective opening gap;
fLanguage
English
Publisher
ieee
Conference_Titel
Nano/Molecular Medicine and Engineering (NANOMED), 2013 IEEE 7th International Conference on
Conference_Location
Phuket
Print_ISBN
978-1-4799-2689-3
Type
conf
DOI
10.1109/NANOMED.2013.6766324
Filename
6766324
Link To Document