Small field-of-view gamma camera for stereotactic breast biopsy
Author
Welch, Benjamin ; Brem, Rachel ; Kross, Brian ; Popov, Vladimir ; Wojcik, Randy ; Majewski, Stan
Author_Institution
Thomas Jefferson Nat. Accelerator Facility, Newport News, VA, USA
Volume
6
fYear
2004
fDate
16-22 Oct. 2004
Firstpage
3858
Abstract
A gamma-ray imaging system has been developed for acquiring stereo images of the distribution of radiopharmaceuticals in breast tissue. The system consists of a small field-of-view gamma-ray camera mounted to a stereotactic biopsy table. The camera is mounted on a rotational arm such that it can be used to image the breast from two 15° stereo views. These stereo images can be used to determine the three dimensional spatial location of a region of focal uptake. Once the location of this region is determined, this information can be used as a guide for stereotactic core needle biopsy. The accuracy that the spatial location of a source could be determined was investigated by moving a point source within the field of view. Measurements indicate that the source could be localized to within 1 mm. A center-of gravity calculation was used to localize the centroid of the image of the source and this was used to determine the spatial location. A comparison of the operation of the gamma imaging system and an X-ray imaging system has been done using a dual modality phantom. These measurements indicate that the spatial location of an isolated source can be determined by the gamma imaging system to within approximately the same accuracy as the X-ray system. Collimators were tested to determine the spatial resolution in the transverse dimension and the impact of this transverse resolution on the axial resolution was investigated. The performance of this gamma-guided stereotactic biopsy system will be presented.
Keywords
biological tissues; collimators; diagnostic radiography; gamma-ray detection; image resolution; mammography; phantoms; X-ray imaging system; breast tissue; center-of gravity calculation; gamma-ray camera; gamma-ray imaging; phantom; radiopharmaceuticals; stereo images; stereo views; stereotactic biopsy table; Breast biopsy; Breast tissue; Cameras; Gravity; Imaging phantoms; Needles; Nuclear imaging; Optical imaging; Spatial resolution; X-ray imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-8700-7
Electronic_ISBN
1082-3654
Type
conf
DOI
10.1109/NSSMIC.2004.1466721
Filename
1466721
Link To Document