DocumentCode :
3548579
Title :
A digital pulse processing system dedicated to CdZnTe detectors
Author :
Montemont, G. ; Moulin, C. ; Isard, J. ; Verger, L.
Author_Institution :
Lab d´Electron. et de Technol. de l´Inf., CEA, Centre d´Etudes Nucleaires de Grenoble
Volume :
7
fYear :
2004
fDate :
16-22 Oct. 2004
Firstpage :
4307
Lastpage :
4311
Abstract :
Pulse processing methods are very useful to improve CdZnTe detectors performances. They allow a fine-tuned compensation of charge loss and bring knowledge on interaction position. We present a theoretical framework for the optimization of bi-parametric systems. A refined digital-based bi-parametric system allowing identification of multiple interactions events is presented and results are discussed
Keywords :
gamma-ray detection; gamma-ray spectrometers; nuclear electronics; semiconductor counters; signal processing; CdZnTe detectors; charge loss; digital pulse processing system; digital signal processing; fine-tuned compensation; gamma-ray detectors; gamma-ray spectrometer; interaction position; multiple interaction events; refined digital-based bi-parametric system; Charge measurement; Current measurement; Detectors; Digital signal processing; Electrons; Energy resolution; Filters; Pulse measurements; Pulse shaping methods; Time measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
Conference_Location :
Rome
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Electronic_ISBN :
1082-3654
Type :
conf
DOI :
10.1109/NSSMIC.2004.1466841
Filename :
1466841
Link To Document :
بازگشت