• DocumentCode
    3548652
  • Title

    Sensing and control in Virgo Experiment

  • Author

    Barsotti, Lisa

  • Author_Institution
    Pisa Univ., Italy
  • Volume
    7
  • fYear
    2004
  • fDate
    16-22 Oct. 2004
  • Firstpage
    4625
  • Abstract
    The gravitational wave detector Virgo is presently under commissioning. A large part of the last year has been spent for control activities, such as the longitudinal locking. This work has been carried out with steps of increasing complexity: locking a simple Fabry-Perot cavity, then a Michelson interferometer with Fabry-Perot cavities in both arms, and finally recycling the light beam into the interferometer.
  • Keywords
    Michelson interferometers; gravitational wave detectors; Fabry-Perot cavity; Michelson interferometer; Virgo Experiment; control activities; feedback control; gravitational wave detector; light beam recycling; longitudinal locking; sensing; Arm; Fabry-Perot; Frequency; Mirrors; Optical feedback; Optical interferometry; Optical noise; Optical sensors; Recycling; Resonance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2004 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-8700-7
  • Electronic_ISBN
    1082-3654
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2004.1466911
  • Filename
    1466911