DocumentCode
3551498
Title
Dependence of pulsed magnetron operation on the centering of the cathode
Author
Becker, G.E.
Volume
1
fYear
1955
fDate
1955
Firstpage
9
Lastpage
9
Abstract
With a fixed frequency 4J52 pulsed magnetron, quantitative results have been obtained for the relations between the cathode position and operating characteristics such as efficiency, frequency pushing, spectrum shape, starting-time jitter, and pulse-to-pulse amplitude and frequency jitter.
Keywords
Cathodes; Frequency modulation; Jitter; Laboratories; Magnetic circuits; Magnetic modulators; Phase modulation; Power generation; Pulse shaping methods; Telephony;
fLanguage
English
Publisher
ieee
Conference_Titel
Electron Devices Meeting, 1955 International
Type
conf
DOI
10.1109/IEDM.1955.186910
Filename
1471957
Link To Document