DocumentCode
3551545
Title
Effects of coefficient of thermal expansion mismatch on solder attached GaAs MMICs
Author
Pavio, J. ; Hyde, D.
Author_Institution
Texas Instrum., Dallas, TX, USA
fYear
1991
fDate
10-14 July 1991
Firstpage
1075
Abstract
The reliability effects of a GaAs solder attachment to a variety of different materials with a diverse range of coefficients of thermal expansion (CTE) are examined. Failure mechanisms included fractures or cracks through the devices, as well as cracking of the corners. GaAs devices are placed under tensile stress with materials such as Kovar experienced severe cracking and corner fracture through long-term reliability screening. Devices placed under compressive stress, on the other hand, did not degrade through life testing unless the CTE mismatch was greater than or equal to 16.5 ppm/ degrees C. From this evaluation, the CTE range at which GaAs can be reliably attached and expected to operate without failures through 1000 cycles of MIL-STD thermal cycling was defined.<>
Keywords
III-V semiconductors; MMIC; circuit reliability; failure analysis; gallium arsenide; integrated circuit testing; life testing; packaging; soldering; thermal expansion; thermal stress cracking; CTE mismatch; GaAs; Kovar; MIL-STD thermal cycling; MMICs; coefficient of thermal expansion; compressive stress; cracks; fractures; life testing; long-term reliability screening; monolithic microwave IC; reliability effects; solder attachment; tensile stress; Assembly; Copper; Gallium arsenide; Inorganic materials; MMICs; Materials reliability; Qualifications; Testing; Thermal expansion; X-rays;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Symposium Digest, 1991., IEEE MTT-S International
Conference_Location
Boston, MA, USA
ISSN
0149-645X
Print_ISBN
0-87942-591-1
Type
conf
DOI
10.1109/MWSYM.1991.147200
Filename
147200
Link To Document