Title :
A novel approach to microwave duplexer tube design
Author :
Gould, L. ; Edwards, E.V. ; Reingold, I.
Abstract :
Utilization of an encapsulated input window with an independent gas fill in a conventional type of broadband duplexer tube separates the interdependence of the high power characteristics. Recovery time and arc loss are determined predominantly by the input window design, whereas spike leakage energy and flat leakage power are determined by the tube body design. The two portions of the tube are designed independently for optimum performance. The effects of geometry, gas pressure, and nature of the gas on the behavior of the high power characteristics have been investigated. The factors determining adequate tube operation combined with reasonable tube life are discussed.
Conference_Titel :
Electron Devices Meeting, 1956 International
DOI :