DocumentCode
3552660
Title
Ruggedized ceramic vidicon
Author
Ochs, S.A. ; Marschka, F.D.
Author_Institution
Radio Corp. of America, Lancaster, Pa.
Volume
13
fYear
1967
fDate
1967
Firstpage
66
Lastpage
66
Abstract
A one-inch vidicon capable of withstanding sterilization treatments and severe environmental testing has been developed for space applications. The tube uses electrostatic focusing and magnetic deflection provided by photoetched deflection coils. The brazed ceramic-and-metal structure has an indium-sealed faceplate and is potted in a magnetic shield. The sterilization tests, consisting of ethylene-oxide exposure and a prolonged 135°C. dry-nitrogen bake, cause some increase in dark current and a small gain in sensitivity of the slow-scan photoconductor. The tube operates satisfactorily after undergoing high-amplitude vibration tests (e.g., 35 g at 2000 Hz and 25 g rms wide-band noise) and after 60 halfsine shock pulses having a 3000-g amplitude) 30 with 100-µ sec rise time, the other 30 with 225- µsec rise time).
Keywords
Ceramics; Coils; Dark current; Electric shock; Electrostatics; Magnetic shielding; Noise level; Photoconductivity; Testing; Wideband;
fLanguage
English
Publisher
ieee
Conference_Titel
Electron Devices Meeting, 1967 International
Type
conf
DOI
10.1109/IEDM.1967.187827
Filename
1474908
Link To Document