    White noise test evaluation of power tubes

  • Author

    Werntz, H.J.

  • Volume
    17
  • fYear
    1971
  • fDate
    1971
  • Firstpage
    140
  • Lastpage
    140
  • Abstract
    This paper discusses a test which measures the linearity characteristics of rf electron power tubes under conditions similar to actual operation such as data transmission. This white noise loading test for power output and signal-to-intermodulation distortion of linear amplifier tubes accomplishes the need for an improved testing technique for the more sophisticated radio communication systems and is specified by Method 2206 of MIL-STD-1311. The test method is explained and compared to the classical "Two-Tone" test. Result of tests performed on RCA linear amplifier power tetrodes demonstrated their inherent linearity. These test results showed similarities and differences to the "Two-Tone" test.
  • Keywords
    Data communication; Distortion measurement; Electron tubes; Linearity; Power amplifiers; Power measurement; Radio communication; Radiofrequency amplifiers; System testing; White noise;