DocumentCode :
3553697
Title :
The peristaltic charge coupled device
Author :
Esser, L.J.M. ; Collet, M.G. ; vanSanten, J.G.
Author_Institution :
Philips Research Laboratories, Eindhoven, Netherlands
Volume :
19
fYear :
1973
fDate :
1973
Firstpage :
17
Lastpage :
20
Abstract :
Starting from the basic transfer principle the operation of the peristaltic charge coupled device is described. Theoretically and experimentally this device is shown to be the most promising of charge transfer devices in terms of charge handling capability, charge transfer inefficiency (ε ≈ 5. 10-5) and operating frequency (f> 100 MHz).
Keywords :
Charge carriers; Charge coupled devices; Charge transfer; Charge-coupled image sensors; Electrodes; Electrons; Frequency; Laboratories; Potential well; Silicon;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electron Devices Meeting, 1973 International
Type :
conf
DOI :
10.1109/IEDM.1973.188635
Filename :
1477512