DocumentCode
3555424
Title
A new measurement technique for the control of the integrity of shielded rooms
Author
Broyde, Frédéric ; Clavelier, Evelyne
Author_Institution
EXCEM, Rueil-Malmaison, France
fYear
1991
fDate
12-16 Aug 1991
Firstpage
106
Lastpage
108
Abstract
An innovative electronic system for measuring and controlling the shielding effectiveness of a screened room is presented. It has the advantage of making continuous measurements possible. The basic property of the system described is that it allows the use of very narrow receiver bandwidth without major cost increase. The two most obvious uses of this narrow bandwidth are an increased sensitivity or an improved immunity
Keywords
measurement systems; shielding; continuous measurements; electronic measurement system; improved immunity; increased sensitivity; narrow receiver bandwidth; shielded rooms; shielding effectiveness; Antenna measurements; Bandwidth; Detectors; Frequency; Magnetic field measurement; Measurement techniques; Optical receivers; Optical transmitters; Receiving antennas; Transmitting antennas;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 1991. Symposium Record., IEEE 1991 International Symposium on
Conference_Location
Cherry Hill, NJ
Print_ISBN
0-7803-0158-7
Type
conf
DOI
10.1109/ISEMC.1991.148194
Filename
148194