DocumentCode :
3555712
Title :
Compact anechoic chamber for immunity test and EMI noise measurement
Author :
Ishino, K. ; Hashimoto, Y. ; Okamura, M. ; Shimizu, Y.
Author_Institution :
TDK Corp., Chiba, Japan
fYear :
1991
fDate :
12-16 Aug 1991
Firstpage :
432
Lastpage :
437
Abstract :
The distribution of the electromagnetic field in the compact anechoic chamber consisting of four walls, ceiling, and floor with ferrite absorbing materials was investigated. The compact anechoic chamber used for both immunity test and electromagnetic interference (EMI) noise measurement was developed by improved ferrite absorber. The compact chamber was extremely uniform, and the maximum deviation is less than 6 dB in the vertical plane. The site attenuation characteristics in the compact chamber were in good agreement with those in the open-field test site
Keywords :
electric noise measurement; electromagnetic interference; electromagnetic wave absorption; interference suppression; EM field distribution; EMI noise measurement; ceiling; compact anechoic chamber; electromagnetic field; electromagnetic interference; ferrite absorbing materials; floor; immunity test; site attenuation characteristics; walls; Anechoic chambers; Antenna measurements; Coordinate measuring machines; Electromagnetic fields; Electromagnetic interference; Ferrites; Floors; Immunity testing; Noise measurement; Transmitting antennas;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 1991. Symposium Record., IEEE 1991 International Symposium on
Conference_Location :
Cherry Hill, NJ
Print_ISBN :
0-7803-0158-7
Type :
conf
DOI :
10.1109/ISEMC.1991.148271
Filename :
148271
Link To Document :
بازگشت