Abstract :
Experimental findings of the testing of two different products using FCC/VDE LISNs from several manufacturers are summarized. The initial problem, inconsistent measurement of emissions, was noted on one UUT; while measurement of emissions on another UUT were consistent. Modifying the grounding of LISN VA #2 allowed more reproducible measurements compared to LISNs VC or VD which meet the impedance specifications and had a low internal ground impedance
Keywords :
electromagnetic interference; electronic equipment testing; measurement standards; EMI; FCC; LISN parameters; UUT; VDE; emissions measurement; grounding; impedance specifications; internal ground impedance; FCC; Grounding; Impedance measurement; Pulp manufacturing; Radiofrequency interference; Reproducibility of results; Resonant frequency; Testing; Virtual colonoscopy;