DocumentCode :
3555795
Title :
Note on EMI measurement at open field test site. 7. Stabilization of power line impedance for radiation measurement
Author :
Maeda, Atsuya ; Kaifuchi, Sumio
fYear :
1991
fDate :
12-16 Aug 1991
Firstpage :
481
Lastpage :
484
Abstract :
For pt.6 see ibid. (1990). Through experiments to establish why measured values of the RF emission level from equipment under test differ according to measuring location, it was confirmed that one of the reasons is derived from the instability in the power line impedance characteristic change. Attempts to define the power line impedance above 30-MHz frequency range provide some solutions to help obtaining identical results in EMI (electromagnetic interference) level
Keywords :
electric field measurement; electric impedance; electromagnetic interference; electronic equipment testing; magnetic field measurement; test facilities; 30 MHz; RF emission level; electromagnetic interference; equipment under test; frequency range; instability; measuring location; open field test site; power line impedance; radiation measurement; stabilisation; Capacitors; Ceramics; Electromagnetic interference; Frequency measurement; Impedance measurement; Power cables; Power measurement; Radio frequency; Resistors; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 1991. Symposium Record., IEEE 1991 International Symposium on
Conference_Location :
Cherry Hill, NJ
Print_ISBN :
0-7803-0158-7
Type :
conf
DOI :
10.1109/ISEMC.1991.148280
Filename :
148280
Link To Document :
بازگشت