DocumentCode :
3556003
Title :
A fifty megawatt klystron for the Stanford Linear Collider
Author :
Lee, T.G. ; Lebacqz, J.V. ; Konrad, G.T.
Author_Institution :
Stanford University, Stanford, CA
Volume :
29
fYear :
1983
fDate :
1983
Firstpage :
144
Lastpage :
147
Abstract :
The proposed Stanford Linear Collider (SLC) has been designed to provide 50 on 50 GeV electron-positron collisions. The performance of the 240 klystrons driving the two-mile long linac must be upgraded to achieve at least 50 Megawatts of peak power output at a pulse width of 5 µsec and a pulse repetition frequency of 180 pulses per second. The operating frequency of the upgraded linac will continue to be 2856 MHz. A klystron amplifier meeting these new requirements has been designed to operate at 315 KV, µk = 2, with a computed efficiency of slightly greater than 50%. Initial tests indicate the achievement of the basic power objectives; however, observed parasitic instabilities make beam focusing, RF drive frequency and drive level extremely critical. High electric fields in the electron gun, output gap and output window are all potential problems. Steps taken in the design to overcome these problems are discussed and test results are presented.
Keywords :
Anodes; Cathodes; Electron beams; Klystrons; Linear particle accelerator; Pulse amplifiers; Radio frequency; Space vector pulse width modulation; Testing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electron Devices Meeting, 1983 International
Type :
conf
DOI :
10.1109/IEDM.1983.190462
Filename :
1483587
Link To Document :
بازگشت