• DocumentCode
    3556868
  • Title

    Coverage and work function of dispenser cathodes

  • Author

    Shroff, A.M. ; Tonnerre, J.C. ; Brion, D.

  • Author_Institution
    THOMSON-CSF, Boulogne-Billancourt, France
  • Volume
    32
  • fYear
    1986
  • fDate
    1986
  • Firstpage
    704
  • Lastpage
    707
  • Abstract
    To predict the potential life of a cathode, it is necessary to know the space charge electron emission, the depletion depth, the coverage evolution and the work function versus temperature and time. Experimental testing on a great number of different cathodes has been performed using diode testing, Auger and X-ray fluorescence spectroscopy to determine optimum activation, operating temperature, and depletion depth at end of life. Using mathematical relations a semi empirical theoritical model has been established in terms of coverage and work function and fractional coverage variations versus time and temperature.
  • Keywords
    Cathodes; Diodes; Electron emission; Fluorescence; Life testing; Mathematical model; Performance evaluation; Space charge; Spectroscopy; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electron Devices Meeting, 1986 International
  • Type

    conf

  • DOI
    10.1109/IEDM.1986.191290
  • Filename
    1486548