Abstract
The analytical expression for the voltage-distortion factor of the network loaded with a three-phase thyristor convertor in bridge connection, which supplies a d.c motor armature, has been derived with neglected active resistance. Calculation results are represented by means of curves with normalised convertor current and source and phase inductance values.
Keywords
DC motors; bridge circuits; electric distortion; electric drives; rectifying circuits; thyristor applications; active resistance; network loaded with thyristor convertor; three phase bridge convertor; thyristor regulated direct current motor drive; voltage distortion factor;