Eliminate Reactive Power and Increase System Efficiency of Isolated Bidirectional Dual-Active-Bridge DC–DC Converters Using Novel Dual-Phase-Shift Control
Author :
Bai, Hua ; Mi, Chris
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Michigan, Dearborn, MI
Volume :
23
Issue :
6
fYear :
2008
Firstpage :
2905
Lastpage :
2914
Abstract :
This paper proposes a novel dual-phase-shift (DPS) control strategy for a dual-active-bridge isolated bidirectional DC-DC converter. The proposed DPS control consists of a phase shift between the primary and secondary voltages of the isolation transformer, and a phase shift between the gate signals of the diagonal switches of each H-bridge. Simulation on a 600-V/5-kW prototype shows that the DPS control has excellent dynamic and static performance compared to the traditional phase-shift control (single phase shift). In this paper, the concept of ldquoreactive powerrdquo is defined, and the corresponding equations are derived for isolated bidirectional DC-DC converters. It is shown that the reactive power in traditional phase-shift control is inherent, and is the main factor contributing to large peak current and large system loss. The DPS control can eliminate reactive power in isolated bidirectional DC-DC converters. In addition, the DPS control can decrease the peak inrush current and steady-state current, improve system efficiency, increase system power capability (by 33%), and minimize the output capacitance as compared to the traditional phase-shift control. The soft-switching range and the influence of short-time-scale factors, such as deadband and system-level safe operation area, are also discussed in detail. Under certain operation conditions, deadband compensation can be implemented easily in the DPS control without a current sensor.
Keywords :
DC-DC power convertors; bridge circuits; reactive power; switching convertors; DPS control strategy; H-bridge diagonal switch; deadband compensation; dual-active-bridge converter; dual-phase-shift control; isolated bidirectional DC-DC converter; isolation transformer; power 5 W; reactive power; soft-switching converter; steady-state current; voltage 600 V; DC–DC converter; DC-DC converter; deadband; dual active bridge (DAB); phase-shift control; reactive power; safe operational area (SOA);
fLanguage :
English
Journal_Title :
Power Electronics, IEEE Transactions on
Publisher :
ieee
Conference_Location :
12/9/2008 12:00:00 AM
ISSN :
0885-8993
Type :
jour
DOI :
10.1109/TPEL.2008.2005103