• DocumentCode
    3559834
  • Title

    Study of slot partial discharges in air-cooled generators

  • Author

    Hudon, Claude ; B?©lec, Mario ; L?©vesque, Melanie

  • Author_Institution
    IREQ, Inst. de Rech. d´´Hydro-Quebec IREQ, Varennes, QC
  • Volume
    15
  • Issue
    6
  • fYear
    2008
  • fDate
    12/1/2008 12:00:00 AM
  • Firstpage
    1675
  • Lastpage
    1690
  • Abstract
    Two laboratory experiments were set up in order to investigate the influence of different parameters on slot partial discharge (PD) activity. The goal of the first experiment was to establish the relative importance of temperature and gap size on slot partial discharges (PDs). The second experiment was used to determine how different stresses (e.g. electrical, thermal and mechanical) influence the discharge mechanisms of stator bars affected by slot PDs. Finally, the results obtained in the laboratory were confirmed when compared with actual field measurements on a generator.
  • Keywords
    electric generators; partial discharges; stators; PD activity; air-cooled generator; slot partial discharge; stator bar; Coatings; Degradation; Insulation; Laboratories; Partial discharges; Stator bars; Temperature; Thermal expansion; Thermal stresses; Vibrations; Slot partial discharges, thermal expansion, generator, stator bars, insulation, semi-conductive coating, gap size, temperature, vibration;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • Conference_Location
    12/1/2008 12:00:00 AM
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2008.4712672
  • Filename
    4712672