• DocumentCode
    3560477
  • Title

    Estimating errors due to sample surface roughness in microwave complex permittivity measurements obtained using a coaxial probe

  • Author

    Arai, M. ; Binner, J.G.P. ; Cross, T.E.

  • Author_Institution
    Dept. of Mater. Eng. & Mater. Design, Nottingham Univ., UK
  • Volume
    31
  • Issue
    2
  • fYear
    1995
  • fDate
    1/19/1995 12:00:00 AM
  • Firstpage
    115
  • Lastpage
    117
  • Abstract
    Complex permittivities of PTFE (Teflon), alumina (Al2O 3) and zirconia (ZrO2) were measured at microwave frequencies using an open-ended coaxial line probe as a function of average surface roughness Ra. Estimates were made and compared with the measurements
  • Keywords
    measurement errors; microwave measurement; permittivity measurement; probes; surface topography; Al2O3; PTFE; Teflon; ZrO2; alumina; coaxial probe; errors estimation; microwave complex permittivity measurement; microwave frequencies; open-ended coaxial line probe; sample surface roughness; zirconia;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • Conference_Location
    1/19/1995 12:00:00 AM
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19950077
  • Filename