DocumentCode :
3560914
Title :
Application of a matched filter approach for finite aperture transducers for the synthetic aperture imaging of defects
Author :
Satyanarayan, L. ; Muralidharan, Ajith ; Krishnamurthy, Chittivenkata ; Balasubramaniam, Krishnan
Author_Institution :
Dept. of Mech. Eng., Indian Inst. of Technol., Madras, Chennai, India
Volume :
57
Issue :
6
fYear :
2010
fDate :
6/1/2010 12:00:00 AM
Firstpage :
1368
Lastpage :
1382
Abstract :
The suitability of the synthetic aperture imaging of defects using a matched filter approach on finite aperture transducers was investigated. The first part of the study involved the use a finite-difference time-domain (FDTD) algorithm to simulate the phased array ultrasonic wave propagation in an aluminum block and its interaction with side-drilled hole-like defects. B-scans were generated using the FDTD method for three active aperture transducer configurations of the phased array (a) single element and (b) 16-element linear scan mode, and (c) 16-element steering mode. A matched filter algorithm (MFA) was developed using the delay laws and the spatial impulse response of a finite size rectangular phased array transducer. The conventional synthetic aperture focusing technique (SAFT) algorithm and the MFA were independently applied on the FDTD signals simulated with the probe operating at a center frequency of 5 MHz and the processed B-scans were compared. The second part of the study investigated the capability of the MFA approach to improve the SNR. Gaussian white noise was added to the FDTD generated defect signals. The noisy B-scans were then processed using the SAFT and the MFA and the improvements in the SNR were estimated. The third part of the study investigated the application of the MFA to image and size surface-crack-like defects in pipe specimens obtained using a 45° steered beam from a phased array probe. These studies confirm that MFA is an alternative to SAFT with little additional computational burden. It can also be applied blindly, like SAFT, to effect synthetic focusing with distinct advantages in treating finite transducer effects, and in handling steered beam inspections. Finally, limitations of the MFA in dealing with larger-sized transducers are discussed.
Keywords :
acoustic transducers; finite difference time-domain analysis; matched filters; materials testing; pipes; ultrasonic imaging; ultrasonic propagation; 16-element linear scan mode; 16-element steering mode; B-scans; Gaussian white noise; delay laws; finite aperture transducers; finite-difference time-domain algorithm; matched filter approach; phased array probe; phased array single element; phased array ultrasonic wave propagation; side-drilled hole-like defects; spatial impulse response; surface-crack-like defects; synthetic aperture focusing; synthetic aperture imaging; Finite difference methods; Focusing; Matched filters; Phased arrays; Probes; Signal to noise ratio; Time domain analysis; Ultrasonic imaging; Ultrasonic transducer arrays; Ultrasonic transducers;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
Conference_Location :
6/1/2010 12:00:00 AM
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2010.1556
Filename :
5480179
Link To Document :
بازگشت