DocumentCode
3562953
Title
A time-delay parallel cascade identification system for predicting jaw movements
Author
Goharian, Nazanin ; Kalani, Hadi ; Moghimi, Sanar
Author_Institution
Electr. Eng. Dept., Ferdowsi Univ. of Mashhad, Mashhad, Iran
fYear
2014
Firstpage
281
Lastpage
286
Abstract
The relationship between muscles´ electrical activity and body movements is of special importance in many medical applications. In this study, for the first time, we plan to evaluate the efficiency of time-delay parallel cascade identification (TDPCI) to predict jaw motion using Electromyography (EMG) signals recorded from two masticatory muscles, namely masseter and temporalis. The Obtained results demonstrate the efficiency of TDPCI in predicting time-varying mastication kinematic parameters based on EMG signals recorded from the two aforementioned muscles. The proposed model has the potential to be employed for controlling masticatory robots controlled by remotely recorded EMG signals.
Keywords
biomechanics; electromyography; medical robotics; medical signal processing; EMG signal; body movement; electromyography; jaw motion; jaw movement prediction; masseter; masticatory robot; muscle electrical activity; temporalis; time-delay parallel cascade identification system; time-varying mastication kinematic parameter; Biomedical engineering; Educational institutions; Electromyography; Kinematics; Muscles; Neural networks; Robots; Electromography (EMG) signals; mastication muscles; time-delay parallel cascade idetification (TDPCI);
fLanguage
English
Publisher
ieee
Conference_Titel
Biomedical Engineering (ICBME), 2014 21th Iranian Conference on
Print_ISBN
978-1-4799-7417-7
Type
conf
DOI
10.1109/ICBME.2014.7043936
Filename
7043936
Link To Document