DocumentCode
3564690
Title
Experimental Measurements and Computer Simulations of FL and CFL for Harmonic Studies
Author
Rawa, Muhyaddin J. H. ; Thomas, David W. P. ; Sumner, Mark
Author_Institution
Electr. Syst. & Opt. Res. Div., Univ. Of Nottingham, Nottingham, UK
fYear
2014
Firstpage
335
Lastpage
339
Abstract
Due to poor efficiencies of Incandescent Lamps (ILs), Fluorescent Lamps (FLs) and Compact Fluorescent Lamps (CFLs) are increasingly used in residential and commercial applications. This proliferation of FLs and CFLs increases the harmonics level in distribution systems that could affect power systems and end users. In order to quantify the harmonics produced by FLs and CFLs precisely, accurate modelling of these loads are required. Matlab Simulink is used to model and simulate the full models of FLs and CFLs to give close results to the experimental measurements. Moreover, a Constant Load Power (CLP) model is also modelled and its results are compared with the full models of FLs and CFLs. This CLP model is much faster to simulate and easier to model than the full model. Such models help engineers and researchers to evaluate the harmonics exist within households and commercial buildings.
Keywords
fluorescent lamps; harmonic analysis; harmonic distortion; power engineering computing; CFL; CLP model; Matlab Simulink; compact fluorescent lamps; computer simulations; constant load power model; experimental measurements; harmonic studies; Fluorescent lamps; Harmonic analysis; Integrated circuit modeling; Load modeling; Mathematical model; Power harmonic filters; Compact Fluorescent Lamp; Fluorescent Lamp; PFC; THD; distortion; harmonics;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer Modelling and Simulation (UKSim), 2014 UKSim-AMSS 16th International Conference on
Print_ISBN
978-1-4799-4923-6
Type
conf
DOI
10.1109/UKSim.2014.13
Filename
7046088
Link To Document