• DocumentCode
    3567680
  • Title

    Electrical fields: What to worry about?

  • Author

    Swenson, David E.

  • Author_Institution
    Affinity Static Control Consulting, LLC, Round Rock, TX, USA
  • fYear
    2012
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    ANSI/ESD S20.20[1] requires keeping insulators with an electrical field of >;2,000 volts @ 1 inch, 12 inches away from unprotected ESD susceptible items. What is the risk from insulators <;2,000 volts @ 1 inch within 12 inches? This paper examines electrical field strength as a function of area and distance.
  • Keywords
    electric fields; electrostatic discharge; insulators; ANSI-ESD S20.20; electrical field strength; insulators; unprotected ESD susceptible items; Discharges (electric); Electric fields; Electrostatic discharges; Glass; Insulators; Metals; Printed circuits;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD), 2012 34th
  • ISSN
    0739-5159
  • Print_ISBN
    978-1-4673-1467-1
  • Type

    conf

  • Filename
    6333306