• DocumentCode
    3569030
  • Title

    Pulsed monoenergy X-ray source

  • Author

    Nianan Cheng

  • Author_Institution
    Inst. of Fluid Phys., Chengdu, China
  • Volume
    1
  • fYear
    1997
  • Firstpage
    843
  • Abstract
    In the paper, a pulsed monoenergy X-ray source which consists of a water dielectric plane pulse forming line and a cold cathode diode is described. The diffraction photograph of K/sub /spl alpha// for copper is observed by applying the LiF crystal. When the copper anode is used, the rate of radiation measured at the detective position is about 6/spl times/10/sup 4/ R/sec. Diffraction photographs of the K/sub /spl alpha// for both copper and zinc are observed simultaneously when the brass anode is used.
  • Keywords
    X-ray production; anodes; cathodes; power supplies to apparatus; pulse generators; pulsed power technology; Cu; CuZn; LiF; anode; brass; cold cathode diode; diffraction photograph; pulsed monoenergy X-ray source; radiation rate; water dielectric plane pulse forming line; Anodes; Cathodes; Copper; Dielectric measurements; Diodes; Position measurement; Radiation detectors; Water resources; X-ray diffraction; Zinc;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 1997. Digest of Technical Papers. 1997 11th IEEE International
  • Print_ISBN
    0-7803-4213-5
  • Type

    conf

  • DOI
    10.1109/PPC.1997.679530
  • Filename
    679530