Abstract
This paper describes the design of a compact electron synchrotron light source for producing X-rays for medical imaging, protein crystallography, nano-machining and other uses up to 35 keV. The source will provide synchrotron light from six 6.9 tesla superconducting 60° bending magnet stations. In addition the ring, contains conventional quadrupoles and sextupoles. The light source has a circumference of 26 meters, which permits it to be located in a variety of industrial and medical facilities
Keywords
X-ray crystallography; X-ray production; X-rays; accelerator magnets; diagnostic radiography; electron accelerators; proteins; radiation therapy; storage rings; superconducting magnets; 1.5 GeV; 35 keV; 6.9 T; X-ray production; compact electron synchrotron light source; industrial facilities; medical imaging; nanomachining; protein crystallography; quadrupoles; sextupoles; superconducting bending magnets; Biomedical imaging; Laboratories; Lattices; Light sources; Paper technology; Particle accelerators; Particle beams; Storage rings; Superconducting magnets; X-ray lasers;